Parsing
Keep ids referenced by labels and ARIA unique
Rule ID: PF-REFERENCED-ID-UNIQUE
- WCAG A
- 4.1.2 Name, Role, Value
- W3C ACT aligned
Why it matters
aria-labelledby, aria-describedby, <label for> and similar references point at an id; if that id appears more than once, browsers use the first match, so a control can be announced with another element's label. This maps to WCAG 4.1.2 (Level A), and Pallyfi reports failures for review.
Who it affects
- Screen reader and other assistive technology users
How to fix it
Rename duplicates so every referenced id is unique. In repeated components such as product cards or form rows, build ids from a record key to avoid collisions.
<label for="qty-1042">Quantity</label>
<input id="qty-1042" type="number" />
<label for="qty-1043">Quantity</label>
<input id="qty-1043" type="number" />How to verify a fix
Scan the page again: the element should no longer be listed for this rule. Then check it the way people use it, for example with a keyboard or a screen reader, since a passing rule shows the markup is right, not that the experience works.
What automated testing can confirm
This is an automated rule that runs on every Pallyfi scan. A pass means the rule found no failing elements in what was rendered at scan time; it doesn’t cover content behind interactions the scan didn’t reach, and some criteria still need a person to check with a keyboard or screen reader. When the rule can’t decide on its own, the element is listed under Needs review instead. Manual audits record human evidence alongside the automated result.
Check your site for this
Quick Scan checks a public page against every rule Pallyfi runs and shows each failing element.