ARIA
Name every meter
Rule ID: PF-METER-NAME
- WCAG A
- 1.1.1 Non-text Content
Why it matters
A role="meter" element reports a value within a known range, such as storage used, and without a name a screen reader reads out the value with no hint of what is being measured. Pallyfi maps this to WCAG 1.1.1 Non-text Content (Level A).
Who it affects
- Blind and low-vision people using screen readers
How to fix it
Name the meter with aria-labelledby pointing at its visible label, or with aria-label or title. Text inside the element does not count as its name for this rule.
<span id="storage-label">Storage used</span>
<div role="meter" aria-labelledby="storage-label" aria-valuenow="68" aria-valuemin="0" aria-valuemax="100" aria-valuetext="68 percent">68%</div>How to verify a fix
Scan the page again: the element should no longer be listed for this rule. Then check it the way people use it, for example with a keyboard or a screen reader, since a passing rule shows the markup is right, not that the experience works.
What automated testing can confirm
This is an automated rule that runs on every Pallyfi scan. A pass means the rule found no failing elements in what was rendered at scan time; it doesn’t cover content behind interactions the scan didn’t reach, and some criteria still need a person to check with a keyboard or screen reader. When the rule can’t decide on its own, the element is listed under Needs review instead. Manual audits record human evidence alongside the automated result.
Check your site for this
Quick Scan checks a public page against every rule Pallyfi runs and shows each failing element.